ZB-K350 Diesel Kerosene Heater
- Heat output
- 100 kW
- Fuel
- Kerosene, diesel
- Fuel tank / cylinder
- 70 L
- Heating volume / area
- 2,000 m³
The models in this group are ZB-K350, PLUS K180, ZB-K175, ZB-H100, ZB-G35T, ZB-G60A. Compare their heat output, power supply, fuel and coverage. Ask us for additional specifications for the exact model you are considering.







| Spec | ZB-K350 | PLUS K180 | ZB-K175 | ZB-H100 | ZB-G35T | ZB-G60A |
|---|---|---|---|---|---|---|
| Power supply | 220V / 50Hz | 110V / 60Hz, 220V / 50Hz | 110V / 60Hz, 220V / 50Hz | 110V / 60Hz, 220V / 50Hz | 220V / 50Hz | 110V / 60Hz |
| Heat output | 100 kW | 51 kW | 51 kW (175,000 BTU) | 30 kW (100,000 BTU) | 12–30 kW (adjustable) | 40,000–60,000 BTU |
| Fuel | Kerosene, diesel | Kerosene, diesel | Kerosene, diesel | Kerosene, diesel | LPG / propane | LPG / propane |
| Fuel tank / cylinder | 70 L | 50 L | 50 L | 50 L | On request | On request |
| Fuel consumption | 9.8 L/h | 4.8 L/h | 4.8 L/h | 2.9 L/h | 0.86–2.16 kg/h | 0.83–1.25 kg/h |
| Heating volume / area | 2,000 m³ | 1,060 m³ | 1,020 m³ | 480 m³ | On request | 234–352 m³ |
| Airflow | On request | On request | On request | On request | 440–600 m³/h | 500 m³/h |
| Regulator / manifold pressure | On request | On request | On request | On request | 700 mbar regulator output | 11.0" W.C. regulator output |
| Ignition / control | Continuous spark ignition; thermostat | Continuous spark ignition; thermostat | Continuous spark ignition; thermostat | Continuous spark ignition; thermostat | On request | Electronic ignition; thermostat |
| Product size | 1310 × 500 × 750 mm | 1130 × 560 × 735 mm | 1060 × 540 × 575 mm | 1100 × 550 × 600 mm | 480 × 225 × 343 mm | 486 × 198 × 335 mm |
| Net / gross weight | 52 / 56.5 kg | 25.6 / 28 kg | 22.3 / 25.8 kg | 30.5 / 33.6 kg | 5.9 / 6.8 kg | 5.6 / 6.6 kg |
| Package size | 1295 × 470 × 690 mm | 1075 × 480 × 545 mm | 1065 × 455 × 500 mm | 1065 × 455 × 500 mm | 530 × 280 × 390 mm | 530 × 245 × 370 mm |
| Container loading (20' / 40' / 40'HQ) | 67 / 138 / 162 pcs | 100 / 200 / 234 pcs | 108 / 220 / 275 pcs | 108 / 220 / 275 pcs | 490 / 950 / 1150 pcs | 570 / 1180 / 1440 pcs |
ZB-K350 is one of the diesel and kerosene forced-air units we build, with a heat output of 100 kW. It runs on Kerosene, diesel and wants a 220V / 50Hz supply. Fuel sits in a 70 L tank or cylinder, and fuel consumption is 9.8 L/h — the two figures buyers most often try to turn into a runtime, which is exactly the step we ask them not to skip past us on. The heating volume is 2,000 m³. What that number can and cannot say about your space is a conversation we have with buyers every week; send the space description with the model code and we will walk through it.
PLUS K180 is one of the diesel and kerosene forced-air units we build, with a heat output of 51 kW. It runs on Kerosene, diesel and wants a 110V / 60Hz, 220V / 50Hz supply. Fuel sits in a 50 L tank or cylinder, and fuel consumption is 4.8 L/h — the two figures buyers most often try to turn into a runtime, which is exactly the step we ask them not to skip past us on. The heating volume is 1,060 m³. What that number can and cannot say about your space is a conversation we have with buyers every week; send the space description with the model code and we will walk through it.
ZB-K175 is one of the diesel and kerosene forced-air units we build, with a heat output of 51 kW (175,000 BTU). It runs on Kerosene, diesel and wants a 110V / 60Hz, 220V / 50Hz supply. Fuel sits in a 50 L tank or cylinder, and fuel consumption is 4.8 L/h — the two figures buyers most often try to turn into a runtime, which is exactly the step we ask them not to skip past us on. The heating volume is 1,020 m³. In practice that figure gets read next to a real space description, and we would rather explain the rating conditions behind it than watch it copied into a project promise it was never measured for.
ZB-H100 is one of the diesel and kerosene forced-air units we build, with a heat output of 30 kW (100,000 BTU). It runs on Kerosene, diesel and wants a 110V / 60Hz, 220V / 50Hz supply. Fuel sits in a 50 L tank or cylinder, and fuel consumption is 2.9 L/h — the two figures buyers most often try to turn into a runtime, which is exactly the step we ask them not to skip past us on. The heating volume is 480 m³. In practice that figure gets read next to a real space description, and we would rather explain the rating conditions behind it than watch it copied into a project promise it was never measured for.
ZB-G35T is a propane unit in our range, with 12–30 kW (adjustable) of heat output. It runs on LPG / propane and wants a 220V / 50Hz supply. Fuel consumption is 0.86–2.16 kg/h.
ZB-G60A is a propane unit in our range, with 40,000–60,000 BTU of heat output. It runs on LPG / propane and wants a 110V / 60Hz supply. Fuel consumption is 0.83–1.25 kg/h. The heating volume is 234–352 m³. In practice that figure gets read next to a real space description, and we would rather explain the rating conditions behind it than watch it copied into a project promise it was never measured for.
Before requesting a quotation, ask us for coverage rating conditions, intended applications and installation instructions for your model. Include the dimensions, controls, packaging and loading details your reviewer needs.
The Salamander vs Torpedo Heater: What Is the Difference? specifications can help with your comparison. Include the exact model code when you ask us for further details.
The Diesel Kerosene Heaters specifications can help with your comparison. Include the exact model code when you ask us for further details.
The Propane Forced Air Heaters specifications can help with your comparison. Include the exact model code when you ask us for further details.
The Torpedo Heater Safety: Ventilation, Placement and Refueling specifications can help with your comparison. Include the exact model code when you ask us for further details.