Propane Forced Air Heaters
ZB-G60A Propane Forced Air Heater
Product overview
ZB-G60A is a propane unit in our range, with 40,000–60,000 BTU of heat output. It runs on LPG / propane and wants a 110V / 60Hz supply. Fuel consumption is 0.83–1.25 kg/h. The heating volume is 234–352 m³. In practice that figure gets read next to a real space description, and we would rather explain the rating conditions behind it than watch it copied into a project promise it was never measured for.

Full specifications
| Power supply | 110V / 60Hz |
|---|---|
| Heat output | 40,000–60,000 BTU |
| Fuel | LPG / propane |
| Fuel consumption | 0.83–1.25 kg/h |
| Heating volume / area | 234–352 m³ |
| Airflow | 500 m³/h |
| Regulator / manifold pressure | 11.0" W.C. regulator output |
| Ignition / control | Electronic ignition; thermostat |
| Product size | 486 × 198 × 335 mm |
| Net / gross weight | 5.6 / 6.6 kg |
| Package size | 530 × 245 × 370 mm |
| Container loading (20' / 40' / 40'HQ) | 570 / 1180 / 1440 pcs |
| MOQ | On request |
Before you request a quote
For propane units, consider the fuel-system hardware alongside heat output. Request cylinder requirements, connection details and a supplied-component list for the exact model. Specify whether your pressure question concerns the regulator or manifold. Ask us for the installation and inspection documents your reviewer needs, and request component details for each model separately.
On ZB-G60A, the coverage entry deserves a second look. What conditions was it rated under? Put your project description next to the model code and ask us, instead of treating the number as a site recommendation. The placement, ventilation and clearance instructions for the arrangement you have in mind need checking too — decide early who does that checking.
Order details to ask about
Quantity and destination, always — a quote without them is a guess. Tell us which dimensions your receiving team works from and in what order they read them, and ask for net and gross weights separately; confusing the two gets expensive at a warehouse door. For a container inquiry, name the container type and ask about packaging for that order. The loading row runs 20-foot / 40-foot / 40-foot high-cube, so keep those headings attached to the figures.
What has to appear on your purchase specification? Send the model code with the fields you want quoted, and keep a visible space for questions nobody has answered yet. Ask for the current sheet and manual with our reply, so your reviewer checks the order against the documents rather than a screenshot of a web page.
Compare specifications
The same fields for the neighbouring models, so the differences show at a glance. Keep each value with its model code and ask us for additional specifications for your selected unit. View the category specifications or browse all models.
| Spec | ZB-G60A | ZB-G35T |
|---|---|---|
| Power supply | 110V / 60Hz | 220V / 50Hz |
| Heat output | 40,000–60,000 BTU | 12–30 kW (adjustable) |
| Fuel | LPG / propane | LPG / propane |
| Fuel consumption | 0.83–1.25 kg/h | 0.86–2.16 kg/h |
| Heating volume / area | 234–352 m³ | On request |
| Airflow | 500 m³/h | 440–600 m³/h |
| Regulator / manifold pressure | 11.0" W.C. regulator output | 700 mbar regulator output |
| Ignition / control | Electronic ignition; thermostat | On request |
| Product size | 486 × 198 × 335 mm | 480 × 225 × 343 mm |
| Net / gross weight | 5.6 / 6.6 kg | 5.9 / 6.8 kg |
| Package size | 530 × 245 × 370 mm | 530 × 280 × 390 mm |
| Container loading (20' / 40' / 40'HQ) | 570 / 1180 / 1440 pcs | 490 / 950 / 1150 pcs |
ZB-G60A FAQ
What is the heat output of ZB-G60A?
ZB-G60A has a heat output of 40,000–60,000 BTU. Adjustable output: On request. Ask us for output-setting details for the exact model.
What fuel does it run, and what supply does it need?
Fuel: LPG / propane. Power supply: 110V / 60Hz. Request the specification sheet and manual for ZB-G60A for your technical review.
What heating volume or area is ZB-G60A rated for?
234–352 m³ is the heating volume rating. Ask us for the rating conditions before using it in a comparison, and keep the unit attached to the value.
What should my receiving team ask for?
Ask which dimensions and which net or gross weights belong on your receiving documents for ZB-G60A. Send the proposed quantity and destination with your request for shipping specifications.
Can I borrow shipping figures from a similar model?
Request packaging and loading details for the exact model and order. Name the container type you are considering and include ZB-G60A in your inquiry.
How do I request further specifications for ZB-G60A?
For minimum order quantity and further specifications, write to us with ZB-G60A, your proposed quantity and the details you need. Request the manual alongside the specification sheet.
Official reference
This agency document is general reading, not a specification. Which of its requirements apply to your equipment and site is a call for the responsible reviewer, made alongside the ZB-G60A manual . Request the model specifications for your review.