Industrial Electric Heaters
ZB-EY3 Electric Fan Heater
Product overview
ZB-EY3 is an electric heater in our range. Its heat output is 29 W / 1,500 W / 3,000 W (three settings). It wants a 220V / 50Hz supply. The heating volume is 60 m³. What that number can and cannot say about your space is a conversation we have with buyers every week; send the space description with the model code and we will walk through it.

Full specifications
| Power supply | 220V / 50Hz |
|---|---|
| Heat output | 29 W / 1,500 W / 3,000 W (three settings) |
| Fuel | On request |
| Heating volume / area | 60 m³ |
| Airflow | 280 m³/h |
| Noise | 51 dB |
| Heating element | Stainless steel |
| Product size | 340 × 310 × 410 mm |
| Net / gross weight | 6.2 / 7.1 kg |
| MOQ | On request |
Before you request a quote
Take the power-supply requirements to your electrical reviewer before selecting a heater. Tell us the voltage and frequency you need and request connection instructions for that version. Ask for the control and protective-device instructions for the exact model. Check the proposed unit against your supply before ordering.
Then there is the question behind the ZB-EY3 coverage figure: under what conditions was it rated? Send the project description with the model code and keep the printed unit in your notes. Placement, ventilation and clearance instructions apply to the arrangement you actually build, not the one in a brochure, so have your reviewer work through them before the selection is final.
Order details to ask about
Quantity and destination, always — a quote without them is a guess. Tell us which dimensions your receiving team works from and in what order they read them, and ask for net and gross weights separately; confusing the two gets expensive at a warehouse door. For a container inquiry, name the container type and ask about packaging for that order. The loading row runs 20-foot / 40-foot / 40-foot high-cube, so keep those headings attached to the figures.
Ask us for this model’s package size, container loading. Include the model code, proposed quantity and destination in your inquiry. Request the specifications for this unit before completing your purchase worksheet.
Compare specifications
The same fields for the neighbouring models, so the differences show at a glance. Keep each value with its model code and ask us for additional specifications for your selected unit. View the category specifications or browse all models.
| Spec | ZB-EY3 | ZB-EC15 | ZB-EY5 | ZB-ET3C | ZB-EC3 | ZB-EF2 |
|---|---|---|---|---|---|---|
| Power supply | 220V / 50Hz | 380V / 50Hz | 380V / 50Hz | 220V / 50Hz | 220V / 50Hz | 220V / 50Hz |
| Heat output | 29 W / 1,500 W / 3,000 W (three settings) | 85 W / 7,000 W / 15 kW (three settings) | 31 W / 2,500 W / 5,000 W (three settings) | 23 W / 1,500 W / 3,000 W (three settings) | 25 W / 1,500 W / 3,000 W (three settings) | 25 W / 1,000 W / 2,000 W (three settings) |
| Heating volume / area | 60 m³ | 300 m³ | 100 m³ | 60 m³ | 60 m³ | 40 m³ |
| Airflow | 280 m³/h | 1,292 m³/h | 320 m³/h | 365 m³/h | 365 m³/h | 120 m³/h |
| Noise | 51 dB | 61 dB | 58 dB | 45 dB | 45 dB | 49 dB |
| Heating element | Stainless steel | Finned stainless steel | Stainless steel | PTC | Finned stainless steel | Stainless steel |
| Product size | 340 × 310 × 410 mm | 645 × 484 × 697 mm | 340 × 310 × 410 mm | 275 × 175 × 318 mm | 250 × 290 × 326 mm | 220 × 200 × 320 mm |
| Net / gross weight | 6.2 / 7.1 kg | 20.1 / 21.5 kg | 7.3 / 8.1 kg | 2.3 / 2.8 kg | 4.0 / 4.6 kg | 3.5 / 4.0 kg |
| Package size | On request | 620 × 410 × 510 mm | 381 × 340 × 425 mm | 300 × 205 × 340 mm | 290 × 300 × 340 mm | 263 × 249 × 350 mm |
| Container loading (20' / 40' / 40'HQ) | On request | 210 / 420 / 520 pcs | 520 / 1000 / 1230 pcs | 1350 / 2600 / 3250 pcs | 950 / 1800 / 2300 pcs | 1300 / 2400 / 2960 pcs |
ZB-EY3 FAQ
What is the heat output of ZB-EY3?
ZB-EY3 has a heat output of 29 W / 1,500 W / 3,000 W (three settings). Adjustable output: On request. Ask us for output-setting details for the exact model.
What fuel does it run, and what supply does it need?
Fuel: On request. Power supply: 220V / 50Hz. Request the specification sheet and manual for ZB-EY3 for your technical review.
What heating volume or area is ZB-EY3 rated for?
60 m³ is the heating volume rating. Ask us for the rating conditions before using it in a comparison, and keep the unit attached to the value.
What should my receiving team ask for?
Ask which dimensions and which net or gross weights belong on your receiving documents for ZB-EY3. Send the proposed quantity and destination with your request for shipping specifications.
Can I borrow shipping figures from a similar model?
Request packaging and loading details for the exact model and order. Name the container type you are considering and include ZB-EY3 in your inquiry.
How do I request further specifications for ZB-EY3?
For minimum order quantity and further specifications, write to us with ZB-EY3, your proposed quantity and the details you need. Request the manual alongside the specification sheet.
Official reference
This agency document is general reading, not a specification. Which of its requirements apply to your equipment and site is a call for the responsible reviewer, made alongside the ZB-EY3 manual . Request the model specifications for your review.