Guide ·

Warehouse Heater Guide for Commercial Spaces

ZB-H100 heater product view for the warehouse heater specification guide

A warehouse heater shortlist usually arrives as a row of model codes and a floor area, and that is exactly where warehouses catch buyers out. Ceiling height, dock doors that never quite close, racking that splits the space into canyons — none of it is in the floor area. Keep the model specifications, by all means. But keep the building questions beside them, or the comparison will look precise and mean very little.

Describe the building before you price the heater

Which rooms or work zones are actually in scope? A whole hall heated to comfort and a picking zone kept frost-free are different orders wearing the same clothes. What operating schedule will the heaters run, what electrical supply is available where they will stand, and are there handling restrictions on fuel inside the building? Who approves the installation? Put those answers in the same document as the model codes. When we quote against a described building, the quote survives contact with the building.

A volume rating is not a building answer

ZB-K350 has a heating-volume rating of 2,000 m³. ZB-K175 is rated at 1,020 m³, PLUS K180 at 1,060 m³, and the electric fan models run smaller — ZB-EY3 and ZB-ET3C at 60 m³ each, ZB-EC15 at 300 m³. Buyers are tempted to divide their hall by one of those numbers and order the result. Resist. Those figures were rated under conditions we can explain; your hall, with its doors and its shifts, is a separate question. Ask for the rating conditions and a review of your building description before the quantity goes on a purchase order.

Think about the day it arrives, and the day it is serviced

Which dimensions and weights go on your receiving plan, and what package information does your warehouse need before the truck is booked? Just as important: who holds the maintenance instructions for each model you take, and where do they live? Ask for the instructions with the model sheet. Handling and service questions that stay unanswered at quotation stage have a habit of returning in January, at the worst possible moment.

Model specification comparison

Compare heat output, fuel, power supply and other specifications for each model. Keep units and qualifiers attached to every value. Ask us for further specifications by model code, and record output settings, consumption, coverage and supply separately.

ZOBO model specifications
ModelHeat outputFuelPower supplyFuel tank / cylinderFuel consumptionHeating volume / areaAirflowIgnition / controlProduct sizeNet / gross weight
ZB-K350100 kWKerosene, diesel220V / 50Hz70 L9.8 L/h2,000 m³On requestContinuous spark ignition; thermostat1310 × 500 × 750 mm52 / 56.5 kg
ZB-K17551 kW (175,000 BTU)Kerosene, diesel110V / 60Hz, 220V / 50Hz50 L4.8 L/h1,020 m³On requestContinuous spark ignition; thermostat1060 × 540 × 575 mm22.3 / 25.8 kg
PLUS K18051 kWKerosene, diesel110V / 60Hz, 220V / 50Hz50 L4.8 L/h1,060 m³On requestContinuous spark ignition; thermostat1130 × 560 × 735 mm25.6 / 28 kg
ZB-EY329 W / 1,500 W / 3,000 W (three settings)On request220V / 50HzOn requestOn request60 m³280 m³/hOn request340 × 310 × 410 mm6.2 / 7.1 kg
ZB-ET3C23 W / 1,500 W / 3,000 W (three settings)On request220V / 50HzOn requestOn request60 m³365 m³/hOn request275 × 175 × 318 mm2.3 / 2.8 kg
ZB-EC1585 W / 7,000 W / 15 kW (three settings)On request380V / 50HzOn requestOn request300 m³1,292 m³/hOn request645 × 484 × 697 mm20.1 / 21.5 kg

Questions for the shortlisted models

ZB-K350

The heating entry is a volume, so ask what conditions it was rated under before it goes anywhere near a project. Your reviewer will want to say what site information travels with the model code — and the proposed application stays a question in that exchange, not a conclusion. Placement, ventilation and clearance instructions from the manual get checked before the selection is treated as final.

ZB-K175

There are two voltage and frequency options, so name the version you want and ask for the connection instructions that belong to it. The model has continuous spark ignition with a thermostat; ask which manual pages explain those controls, and send any control questions you cannot close with the model code attached. A question labelled ZB-K175 gets answered for ZB-K175.

PLUS K180

Ask for the manual behind the ignition and thermostat entries, and which control instructions accompany the order. On shipping, be precise about whether you mean the unit or its packaging — then confirm which net and gross figures go on your receiving documents and what packaging detail needs confirming for this order. Similar outputs elsewhere in the range do not answer for this code.

ZB-EY3

Package size and container loading are On request for this model, so tell us what your shipping inquiry needs for this code and quantity — and request shipping details for this exact model. Have your receiving team state the dimension order and weight labels they work to, and put those requirements in the message.

ZB-ET3C

This model has a PTC heating element. Ask for the manual pages covering its output settings and controls for your purchase specification. Which voltage and frequency should the offer state? Connection, inspection and supplied-document questions go with the exact code, not under a general electric-heater heading.

ZB-EC15

Read the heat row exactly as printed; it carries separate entries, and collapsing them into one setting would misquote the unit. Ask which entry your specification needs and request the control and supply instructions that explain it. Your electrical reviewer should say what they require before this version is written into a purchase specification.

Build the quotation worksheet

One column per model code. Printed values first, supplier answers next, then the receiving and service questions your warehouse raised — dimensions, package entries, who holds the maintenance instructions. When a field reads On request, the inquiry names it; the answer comes back attached to a code, not to a category.

Transcribe the heat row in full, with its unit and qualifiers. Do not convert a consumption figure into a runtime or a volume rating into a building promise; ask for the rated conditions and the manual instead, and keep your building description clipped to the same worksheet so the two are reviewed together.

Buyer confirmation checklist

  • Is the exact model code on every request for a missing field?
  • Does the inquiry describe zones, schedule and available supply?
  • Which voltage and frequency must the quotation confirm?
  • Are volume figures kept apart from any building-level decision?
  • What conditions accompany the rated heating volume?
  • Which fuel and handling restrictions apply inside the building?
  • Who holds the maintenance instructions for each selected model?
  • Which dimensions, weights and package entries go on the receiving plan?

From here, warehouse buyers usually split two ways: deeper into the model fields, or out to the building questions. Both routes are below; the model code travels with you either way.

Open Diesel Kerosene Heaters. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.

Open Propane vs Diesel Forced Air Heater. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.

Open Industrial Electric Heaters. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.

Open How to Size an Industrial Heater. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.

Open OEM inquiry details. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.

Open Construction Site Heating: How to Choose a Construction Heater. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.

Questions to close before ordering

What should travel with the model code?

Quantity, the specifications under comparison, the entries still open — and the building description: zones, schedule, available supply, handling restrictions. Add who approves the installation and ask for sheet and manual together.

How do we record a field nobody has answered?

On request, against that code. Package and loading figures especially: another model’s carton is not your carton. Answers enter the worksheet with their units attached.

Can we divide the hall by a rated volume to get a quantity?

That arithmetic skips every condition the rating was measured under. Ask for those conditions and a review of your building description; the quantity follows that review, not the other way round.

Official references

The agency documents below are general reading, and worth an hour of your reviewer’s time. Which parts apply to the proposed equipment and your site is their call to make, checked against the exact model manual. Review the requirements alongside the specifications for your selected model.

Need model specs or factory pricing?

Get a Quote