Diesel Kerosene Heaters
PLUS K180 Diesel Kerosene Heater
Product overview
PLUS K180 is one of the diesel and kerosene forced-air units we build, with a heat output of 51 kW. It runs on Kerosene, diesel and wants a 110V / 60Hz, 220V / 50Hz supply. Fuel sits in a 50 L tank or cylinder, and fuel consumption is 4.8 L/h — the two figures buyers most often try to turn into a runtime, which is exactly the step we ask them not to skip past us on. The heating volume is 1,060 m³. What that number can and cannot say about your space is a conversation we have with buyers every week; send the space description with the model code and we will walk through it.

Full specifications
| Power supply | 110V / 60Hz, 220V / 50Hz |
|---|---|
| Heat output | 51 kW |
| Fuel | Kerosene, diesel |
| Fuel tank / cylinder | 50 L |
| Fuel consumption | 4.8 L/h |
| Heating volume / area | 1,060 m³ |
| Ignition / control | Continuous spark ignition; thermostat |
| Product size | 1130 × 560 × 735 mm |
| Net / gross weight | 25.6 / 28 kg |
| Package size | 1075 × 480 × 545 mm |
| Container loading (20' / 40' / 40'HQ) | 100 / 200 / 234 pcs |
| MOQ | On request |
Before you request a quote
Start with the fuel for your diesel heater. Request the fuel-grade, filling and storage instructions for this model from us, together with the conditions behind its consumption figure. If your worksheet needs a runtime, request a documented value for this code. Dividing tank capacity by consumption does not establish a runtime specification.
Then there is the question behind the PLUS K180 coverage figure: under what conditions was it rated? Send the project description with the model code and keep the printed unit in your notes. Placement, ventilation and clearance instructions apply to the arrangement you actually build, not the one in a brochure, so have your reviewer work through them before the selection is final.
Order details to ask about
Quantity and destination, always — a quote without them is a guess. Tell us which dimensions your receiving team works from and in what order they read them, and ask for net and gross weights separately; confusing the two gets expensive at a warehouse door. For a container inquiry, name the container type and ask about packaging for that order. The loading row runs 20-foot / 40-foot / 40-foot high-cube, so keep those headings attached to the figures.
What has to appear on your purchase specification? Send the model code with the fields you want quoted, and keep a visible space for questions nobody has answered yet. Ask for the current sheet and manual with our reply, so your reviewer checks the order against the documents rather than a screenshot of a web page.
Compare specifications
The same fields for the neighbouring models, so the differences show at a glance. Keep each value with its model code and ask us for additional specifications for your selected unit. View the category specifications or browse all models.
| Spec | PLUS K180 | ZB-K350 | ZB-K175 | ZB-H100 |
|---|---|---|---|---|
| Power supply | 110V / 60Hz, 220V / 50Hz | 220V / 50Hz | 110V / 60Hz, 220V / 50Hz | 110V / 60Hz, 220V / 50Hz |
| Heat output | 51 kW | 100 kW | 51 kW (175,000 BTU) | 30 kW (100,000 BTU) |
| Fuel | Kerosene, diesel | Kerosene, diesel | Kerosene, diesel | Kerosene, diesel |
| Fuel tank / cylinder | 50 L | 70 L | 50 L | 50 L |
| Fuel consumption | 4.8 L/h | 9.8 L/h | 4.8 L/h | 2.9 L/h |
| Heating volume / area | 1,060 m³ | 2,000 m³ | 1,020 m³ | 480 m³ |
| Ignition / control | Continuous spark ignition; thermostat | Continuous spark ignition; thermostat | Continuous spark ignition; thermostat | Continuous spark ignition; thermostat |
| Product size | 1130 × 560 × 735 mm | 1310 × 500 × 750 mm | 1060 × 540 × 575 mm | 1100 × 550 × 600 mm |
| Net / gross weight | 25.6 / 28 kg | 52 / 56.5 kg | 22.3 / 25.8 kg | 30.5 / 33.6 kg |
| Package size | 1075 × 480 × 545 mm | 1295 × 470 × 690 mm | 1065 × 455 × 500 mm | 1065 × 455 × 500 mm |
| Container loading (20' / 40' / 40'HQ) | 100 / 200 / 234 pcs | 67 / 138 / 162 pcs | 108 / 220 / 275 pcs | 108 / 220 / 275 pcs |
PLUS K180 FAQ
What is the heat output of PLUS K180?
PLUS K180 has a heat output of 51 kW. Adjustable output: On request. Ask us for output-setting details for the exact model.
What fuel does it run, and what supply does it need?
Fuel: Kerosene, diesel. Power supply: 110V / 60Hz, 220V / 50Hz. Request the specification sheet and manual for PLUS K180 for your technical review.
What heating volume or area is PLUS K180 rated for?
1,060 m³ is the heating volume rating. Ask us for the rating conditions before using it in a comparison, and keep the unit attached to the value.
What should my receiving team ask for?
Ask which dimensions and which net or gross weights belong on your receiving documents for PLUS K180. Send the proposed quantity and destination with your request for shipping specifications.
Can I borrow shipping figures from a similar model?
Request packaging and loading details for the exact model and order. Name the container type you are considering and include PLUS K180 in your inquiry.
How do I request further specifications for PLUS K180?
For minimum order quantity and further specifications, write to us with PLUS K180, your proposed quantity and the details you need. Request the manual alongside the specification sheet.
Official reference
This agency document is general reading, not a specification. Which of its requirements apply to your equipment and site is a call for the responsible reviewer, made alongside the PLUS K180 manual . Request the model specifications for your review.