Diesel Kerosene Heaters
PLUS K180 Diesel Kerosene Heater
Product overview
PLUS K180 has a listed heat output of 51 kW. Fuel: Kerosene, diesel. Power supply: 110V / 60Hz, 220V / 50Hz. Fuel tank / cylinder: 50 L. Heating volume: 1,060 m³. Fuel consumption: 4.8 L/h.

Full specifications
| Power supply | 110V / 60Hz, 220V / 50Hz |
|---|---|
| Heat output | 51 kW |
| Fuel | Kerosene, diesel |
| Fuel tank / cylinder | 50 L |
| Fuel consumption | 4.8 L/h |
| Heating volume / area | 1,060 m³ |
| Ignition / control | Continuous spark ignition; thermostat |
| Product size | 1130 × 560 × 735 mm |
| Net / gross weight | 25.6 / 28 kg |
| Package size | 1075 × 480 × 545 mm |
| Container loading (20' / 40' / 40'HQ) | 100 / 200 / 234 pcs |
| MOQ | On request |
Before you request a quote
Start with the fuel instructions. Which fuel grades does the manual specify, and what filling and storage instructions should accompany your order? Ask for the conditions behind the consumption entry. If you need a runtime figure, request documentation for it rather than calculating one from the tank and consumption rows.
For PLUS K180, which rating conditions accompany the heating volume or area entry? Send your project description and ask for a model-specific review. Keep the stated unit on your worksheet. What placement, ventilation and clearance instructions apply to the arrangement you have in mind? Who will check those instructions before you select the equipment?
Order details to ask about
Include your quantity and delivery destination. Which dimensions does your receiving team need, and in what order should they be read? Ask about net and gross weights separately. For a container inquiry, specify the container type and ask about the packaging for that order. The loading row uses 20-foot / 40-foot / 40-foot high-cube order; keep those headings attached to the figures.
What needs to appear on your purchase specification? Send the model code with the fields you want quoted, and keep a separate space for unanswered questions. Ask for the current sheet and manual so your reviewer can check the proposed order against the documents.
Compare listed fields
Compare the exact model entries below. Keep each value with its model code; missing entries are On request. View the category specifications or browse all published models for another field comparison.
| Spec | PLUS K180 | ZB-K350 | ZB-K175 | ZB-H100 |
|---|---|---|---|---|
| Power supply | 110V / 60Hz, 220V / 50Hz | 220V / 50Hz | 110V / 60Hz, 220V / 50Hz | 110V / 60Hz, 220V / 50Hz |
| Heat output | 51 kW | 100 kW | 51 kW (175,000 BTU) | 30 kW (100,000 BTU) |
| Fuel | Kerosene, diesel | Kerosene, diesel | Kerosene, diesel | Kerosene, diesel |
| Fuel tank / cylinder | 50 L | 70 L | 50 L | 50 L |
| Fuel consumption | 4.8 L/h | 9.8 L/h | 4.8 L/h | 2.9 L/h |
| Heating volume / area | 1,060 m³ | 2,000 m³ | 1,020 m³ | 480 m³ |
| Ignition / control | Continuous spark ignition; thermostat | Continuous spark ignition; thermostat | Continuous spark ignition; thermostat | Continuous spark ignition; thermostat |
| Product size | 1130 × 560 × 735 mm | 1310 × 500 × 750 mm | 1060 × 540 × 575 mm | 1100 × 550 × 600 mm |
| Net / gross weight | 25.6 / 28 kg | 52 / 56.5 kg | 22.3 / 25.8 kg | 30.5 / 33.6 kg |
| Package size | 1075 × 480 × 545 mm | 1295 × 470 × 690 mm | 1065 × 455 × 500 mm | 1065 × 455 × 500 mm |
| Container loading (20' / 40' / 40'HQ) | 100 / 200 / 234 pcs | 67 / 138 / 162 pcs | 108 / 220 / 275 pcs | 108 / 220 / 275 pcs |
PLUS K180 FAQ
What output is listed for PLUS K180?
PLUS K180 lists heat output as 51 kW. Adjustable output: On request. Keep the listed settings and qualifiers with the output entry in your specification request.
What fuel and supply fields are listed?
For PLUS K180, fuel is Kerosene, diesel; power supply is 110V / 60Hz, 220V / 50Hz. Ask for any missing supply details in the model sheet and manual.
What heating volume or area is listed?
The heating volume entry for PLUS K180 is 1,060 m³. Ask for the conditions accompanying this rating and keep its unit when preparing your comparison.
What should I ask about receiving the order?
Ask which dimensions and net or gross weights should appear on your receiving documents. What handling information does your team need for PLUS K180? Send those questions with the proposed quantity and destination; any unlisted dimension or weight stays On request.
Can I use another model's shipping details?
Request packaging and loading details for this code and your proposed order. Which container type are you considering, and what package information do you need? Keep the answer attached to PLUS K180 rather than copying a neighboring model's entries into your shipment request.
How do I request missing details for PLUS K180?
Minimum order quantity and any unlisted field are On request. Include PLUS K180, the quantity and the specific fields you need confirmed. Request the model manual with the specification sheet.
Official reference
Review this agency document as general reference reading. Which requirements apply to the proposed equipment and site? Ask the responsible reviewer to check its scope alongside the PLUS K180 manual. The model specifications on this page remain the listed fields above.