ZB-G60A Propane Forced Air Heater
- Heat output
- 40,000–60,000 BTU
- Fuel
- LPG / propane
- Heating volume / area
- 234–352 m³
- Power supply
- 110V / 60Hz
The models in this group are ZB-G60A, ZB-G35T. Compare their heat output, power supply, fuel and coverage. Ask us for additional specifications for the exact model you are considering.



| Spec | ZB-G60A | ZB-G35T |
|---|---|---|
| Power supply | 110V / 60Hz | 220V / 50Hz |
| Heat output | 40,000–60,000 BTU | 12–30 kW (adjustable) |
| Fuel | LPG / propane | LPG / propane |
| Fuel consumption | 0.83–1.25 kg/h | 0.86–2.16 kg/h |
| Heating volume / area | 234–352 m³ | On request |
| Airflow | 500 m³/h | 440–600 m³/h |
| Regulator / manifold pressure | 11.0" W.C. regulator output | 700 mbar regulator output |
| Ignition / control | Electronic ignition; thermostat | On request |
| Product size | 486 × 198 × 335 mm | 480 × 225 × 343 mm |
| Net / gross weight | 5.6 / 6.6 kg | 5.9 / 6.8 kg |
| Package size | 530 × 245 × 370 mm | 530 × 280 × 390 mm |
| Container loading (20' / 40' / 40'HQ) | 570 / 1180 / 1440 pcs | 490 / 950 / 1150 pcs |
ZB-G60A is a propane unit in our range, with 40,000–60,000 BTU of heat output. It runs on LPG / propane and wants a 110V / 60Hz supply. Fuel consumption is 0.83–1.25 kg/h. The heating volume is 234–352 m³. In practice that figure gets read next to a real space description, and we would rather explain the rating conditions behind it than watch it copied into a project promise it was never measured for.
ZB-G35T is a propane unit in our range, with 12–30 kW (adjustable) of heat output. It runs on LPG / propane and wants a 220V / 50Hz supply. Fuel consumption is 0.86–2.16 kg/h.
Before requesting a quotation, ask us for coverage rating conditions, intended applications and installation instructions for your model. Include the dimensions, controls, packaging and loading details your reviewer needs.
The Diesel Kerosene Heaters specifications can help with your comparison. Include the exact model code when you ask us for further details.
The Propane vs Diesel Forced Air Heater specifications can help with your comparison. Include the exact model code when you ask us for further details.
The Torpedo Heaters specifications can help with your comparison. Include the exact model code when you ask us for further details.
For both ZB-G35T and ZB-G60A, request cylinder requirements, connection details and a supplied-component list before comparing quotes; on propane units, that list is where similar-looking prices stop being similar.