Guide ·
Salamander vs Torpedo Heater: What Is the Difference?

The salamander vs torpedo heater question comes up in quotations all the time, usually as two offers that look comparable and are not. One names a category, the other names a model. Ours is a simple position: a category word can start a conversation, but only a model code can finish one. Compare our torpedo heater models by their specifications, and request the same details with each offer you receive.
Make the quotation name a model
If an offer says only “torpedo heater” or “salamander,” ask which exact model it describes and request the field-by-field sheet for that unit. Which construction details and supplied components come with it, and which uses is it designed for? Write those questions next to the name on the offer. Answers that cannot be tied to one unit cannot be compared, and they cannot be enforced later either.
Diesel and propane specifications
ZB-H100, ZB-K175, PLUS K180 and ZB-K350 run on kerosene and diesel and have fuel tanks. ZB-G35T and ZB-G60A run on LPG / propane. Ask us for cylinder details for each propane model. What fuel-system components are included with each proposed order? Get the component list for the exact code, in writing, before the prices are allowed to look similar.
Labels in the inquiry, numbers in the table
Keep the category label in your inquiry if it helps the conversation — just never let it into the specification table. There, what counts is the output unit as printed, the supply voltage, the weight entry, the controls for that model. Anything missing goes in as a question against the model code. It is a small discipline, and it is the whole difference between a comparison and a collage.
Model specification comparison
Compare heat output, fuel, power supply and other specifications for each model. Keep units and qualifiers attached to every value. Ask us for further specifications by model code, and record output settings, consumption, coverage and supply separately.
| Model | Heat output | Fuel | Power supply | Fuel tank / cylinder | Fuel consumption | Heating volume / area | Airflow | Ignition / control | Product size | Net / gross weight |
|---|---|---|---|---|---|---|---|---|---|---|
| ZB-H100 | 30 kW (100,000 BTU) | Kerosene, diesel | 110V / 60Hz, 220V / 50Hz | 50 L | 2.9 L/h | 480 m³ | On request | Continuous spark ignition; thermostat | 1100 × 550 × 600 mm | 30.5 / 33.6 kg |
| ZB-K175 | 51 kW (175,000 BTU) | Kerosene, diesel | 110V / 60Hz, 220V / 50Hz | 50 L | 4.8 L/h | 1,020 m³ | On request | Continuous spark ignition; thermostat | 1060 × 540 × 575 mm | 22.3 / 25.8 kg |
| PLUS K180 | 51 kW | Kerosene, diesel | 110V / 60Hz, 220V / 50Hz | 50 L | 4.8 L/h | 1,060 m³ | On request | Continuous spark ignition; thermostat | 1130 × 560 × 735 mm | 25.6 / 28 kg |
| ZB-K350 | 100 kW | Kerosene, diesel | 220V / 50Hz | 70 L | 9.8 L/h | 2,000 m³ | On request | Continuous spark ignition; thermostat | 1310 × 500 × 750 mm | 52 / 56.5 kg |
| ZB-G35T | 12–30 kW (adjustable) | LPG / propane | 220V / 50Hz | On request | 0.86–2.16 kg/h | On request | 440–600 m³/h | On request | 480 × 225 × 343 mm | 5.9 / 6.8 kg |
| ZB-G60A | 40,000–60,000 BTU | LPG / propane | 110V / 60Hz | On request | 0.83–1.25 kg/h | 234–352 m³ | 500 m³/h | Electronic ignition; thermostat | 486 × 198 × 335 mm | 5.6 / 6.6 kg |
Questions for the shortlisted models
ZB-H100
This model runs on kerosene and diesel. Specify your chosen fuel and request its grade and filling instructions. If the quotation needs a running-time figure, ask for a documented one for this model and the conditions attached to it. Then let your reviewer work through the operating instructions before the price hardens into a decision.
ZB-K175
There are two voltage and frequency options, so name the version you want and ask for the connection instructions that belong to it. The model has continuous spark ignition with a thermostat; ask which manual pages explain those controls, and send any control questions you cannot close with the model code attached. A question labelled ZB-K175 gets answered for ZB-K175.
PLUS K180
Ask for the manual behind the ignition and thermostat entries, and which control instructions accompany the order. On shipping, be precise about whether you mean the unit or its packaging — then confirm which net and gross figures go on your receiving documents and what packaging detail needs confirming for this order. Similar outputs elsewhere in the range do not answer for this code.
ZB-K350
The heating entry is a volume, so ask what conditions it was rated under before it goes anywhere near a project. Your reviewer will want to say what site information travels with the model code — and the proposed application stays a question in that exchange, not a conclusion. Placement, ventilation and clearance instructions from the manual get checked before the selection is treated as final.
ZB-G35T
Regulator pressure is its own field here, separate from output and airflow, so ask which regulator and connection details accompany the offer. Request the supplied-component list for this code. Request cylinder, ignition and protective-device details for this model and include them in your site review.
ZB-G60A
This model has electronic ignition and a thermostat — ask which instructions explain those controls and what inspection information the manual provides. Then the fuel system: which components are included in the proposed order, and which cylinder and connection details are still unanswered? Keep the unanswered ones beside this code on the worksheet until they are not unanswered anymore.
Build the quotation worksheet
Build the worksheet around model codes and refuse every entry that will not attach to one. Printed values in the first columns, supplier answers beside them, and a visible home for the questions the offers have not answered — components, construction, permitted uses.
Where an offer arrives wearing only a category name, its column stays empty until a model sheet fills it. Copy heat rows whole, keep units welded to their numbers, and treat any consumption-to-runtime conversion as what it is: an unmeasured figure that should be replaced by a documented one.
Buyer confirmation checklist
- Does every offer name an exact model code?
- Is a field-by-field sheet attached to each named model?
- Which output unit is printed — kW or BTU — and is it copied intact?
- What fuel-system components are included, per code, in writing?
- Have you requested control specifications for the exact model?
- Which construction and installation details remain open in the manual?
- Are category labels kept out of the specification table?
- Who approves the proposed application on your side?
Follow up with the relevant specifications and guides
If this comparison has done its job, every offer you hold now has a model code attached. The pages below take that discipline further — specifications first, labels last.
Open Torpedo Heaters. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open Propane Convection Heaters. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open ZB-H100 specifications. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open ZB-K175 specifications. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open PLUS K180 specifications. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open ZB-K350 specifications. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open Diesel vs Kerosene: Which Fuel for a Forced Air Heater?. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open Propane Forced Air Heaters. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open Propane vs Diesel Forced Air Heater. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open Torpedo Heater Safety: Ventilation, Placement and Refueling. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Open OEM inquiry details. What is still unanswered about the proposed unit? Add it to the worksheet and request the documentation with your quote.
Questions to close before ordering
What should travel with the model code?
Everything, starting with the insistence that there is one. Quantity, compared fields, open entries — and if an offer names only a category, the request that it name a model and produce that model’s sheet.
How do we record a field nobody has answered?
On request, in the column of the exact code. A value copied from the model above it in the table is the most expensive kind of tidy.
Does the category name on the category page limit what we can ask?
No. Ask for construction, components and permitted uses for the proposed model. The manual answers; the label cannot.
Official references
The agency documents below are general reading, and worth an hour of your reviewer’s time. Which parts apply to the proposed equipment and your site is their call to make, checked against the exact model manual. Review the requirements alongside the specifications for your selected model.
Need model specs or factory pricing?
Get a Quote